Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
1.
World J Gastroenterol ; 30(12): 1706-1713, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38617738

RESUMO

Endoscopic resection (ER) of colorectal polyps has become a daily practice in most endoscopic units providing a colorectal cancer screening program and requires the availability of local experts and high-end endoscopic devices. ER procedures have evolved over the past few years from endoscopic mucosal resection (EMR) to more advanced techniques, such as endoscopic submucosal dissection and endo-scopic full-thickness resection. Complete resection and disease eradication are the ultimate goals of ER-based techniques, and novel devices have been developed to achieve these goals. The EndoRotor® Endoscopic Powered Resection System (Interscope Medical, Inc., Northbridge, Massachusetts, United States) is one such device. The EndoRotor is a powered resection tool for the removal of alimentary tract mucosa, including post-EMR persistent lesions with scarring, and has both CE Mark and FDA clearance. This review covers available published evidence documenting the usefulness of EndoRotor for the management of recurrent colorectal polyps.


Assuntos
Pólipos do Colo , Endometriose , Humanos , Feminino , Cicatriz , Pólipos do Colo/cirurgia , Endoscopia , Erradicação de Doenças
2.
Endosc Int Open ; 12(3): E402-E412, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38504742

RESUMO

Background and study aims The aim of this study was to assess the effect of an educational video on the quality of bowel preparation of patients from a UK population attending for their first colonoscopy. Patients and methods A prospective, endoscopist-blinded trial with 1:1 allocation was performed. Patients referred for their first colonoscopy were recruited between February 2019 and December 2019. All participants were prescribed Moviprep and received the trial site's standard written bowel preparation instructions, with the intervention group also receiving a bespoke educational video. Adequacy of bowel preparation (defined as a Boston Bowel Preparation Scale of ≥2 in each segment of the bowel) and polyp detection rates (PDRs) were compared. Fisher's chi squared test was utilized with P <0.05 as the threshold for significance. Results A total of 509 participants completed the trial from six centers; 251 were randomized to the intervention group. The mean age was 57 years and 52.3% were female. The primary endpoint was met with an adequacy rate of 216 of 251 (86.1%) in the intervention group, compared with 205 of 259 (79.1%) in the control group ( P <0.05, odds ratio [OR] 1.626, 95% CI 1.017-2.614). The PDR was significantly higher in the intervention group (39% vs 30%, OR 1.51, 95% CI 1.04-2.19, P <0.05). Conclusions An educational video leads to improved bowel preparation for patients attending for their first colonoscopy, and is also associated with greater detection of polyps. Widespread adoption of an educational video incurs minimal investment, but would reduce the number of inadequate procedures, missed pathology, and the cost that both these incur.

3.
Cir Cir ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38467075

RESUMO

Objective: Screening is an effective tool for detecting colorectal lesions in asymptomatic subjects. There is a positive correlation between fecal immunochemical test (FIT) values and the size of tumors. Despite the efficacy of screening, the detection of colorectal cancer (CRC) remains low. The primary objective was to evaluate the best FIT cutoff value for detecting advanced adenomas and CRC among individuals at average risk in a country with a high incidence and morbidity from CRC. Methods: This observational and prospective study analyzed consecutive cases in 1461 asymptomatic subjects with a positive FIT (≥ 100 ng hemoglobin [Hb]/mL) referred for colonoscopy (2012-2015) at a tertiary center in Uruguay. Results: Colorectal lesions were detected in 35.3% (516/1461) of cases, with a mean age of 62.8 ± 8.3 years. About 53.2% were men and 65.1% of the tumors were located in the left side of the colon. The size of the lesion and FIT values (p = 0.001) were positively correlated. Laterally spreading tumors predominated in the right colon (586 ng Hb/mL; 95% Confidence interval [CI] 443.4-760). One hundred and thirty-five (26%) lesions were advanced adenomas (15 ± 6.7 mm); 694.6 ng/mL; 95% CI 632.4-756.9). The highest diagnostic yield (0.5112) for advanced adenomas was at a FIT level of 400 ng Hb/mL (accuracy 88.6%). There were significant differences in FIT values early and advanced CRC (927 ng/mL; [95% CI: 637-1082] vs. 1453 [95% CI: 1352-1594; p = 0.001]). Conclusion: A FIT value of 400 ng Hb/mL was the best diagnostic yield to detect advanced adenomas and CRC. This value is useful during the COVID-19 pandemic as it allows prioritization of colonoscopy to those most at risk of significant disease, thus reducing risks to both patients and healthcare workers.


Objetivo: El cribado es una herramienta eficaz para detectar lesiones colorrectales en sujetos asintomáticos. Existe una correlación positiva entre los valores de la prueba inmunoquímica fecal (FIT) y el tamaño de los tumores. A pesar de la eficacia del cribado, la detección del cáncer colorrectal (CCR) sigue siendo baja. El objetivo principal fue evaluar el mejor valor de corte FIT para detectar adenomas avanzados y CCR entre personas con riesgo promedio en un país con alta incidencia y morbilidad por CCR. Métodos: Este estudio observacional y prospectivo analizó 1461 sujetos asintomáticos con FIT positivo (≥ 100 ng de hemoglobina [Hb]/mL) remitidos para colonoscopia (2012-2015) en un centro terciario en Uruguay. Resultados: Se detectaron lesiones colorrectales en el 35,3% (516/1461) de los casos, con una edad media de 62,8 ± 8,3 años. Alrededor del 53,2% eran hombres y el 65,1% de los tumores estaban ubicados en el lado izquierdo del colon. El tamaño de la lesión y los valores FIT (p = 0,001) se correlacionaron positivamente. Los tumores con extensión lateral predominaron en el colon derecho (586 ng Hb/mL; intervalo de confianza [IC] del 95%: 443,4-760). Ciento treinta y cinco (26%) lesiones fueron adenomas avanzados (15 ± 6,7 mm); 694,6 ng/ml; IC 95% 632,4-756,9). El rendimiento diagnóstico más alto (0,5112) para los adenomas avanzados se obtuvo con un nivel FIT de 400 ng Hb/ml (precisión del 88,6%). Hubo diferencias significativas en los valores de FIT de CCR temprano y avanzado (927 ng/mL; [IC 95%: 637-1082] vs. 1453 [IC 95%: 1352-1594; p = 0,001]). Conclusión: Un valor FIT de 400 ng Hb/mL fue el mejor rendimiento diagnóstico para detectar adenomas avanzados y CCR. Este valor es útil durante la pandemia de COVID-19, ya que permite priorizar la colonoscopia a aquellos con mayor riesgo de padecer una enfermedad importante, reduciendo así los riesgos tanto para los pacientes como para los trabajadores de la salud.

4.
Dis Esophagus ; 37(3)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-37899140

RESUMO

Esophagogastroduodenoscopies (EGD) are aerosol-generating procedures that may spread respiratory pathogens. We aim to investigate the production of airborne aerosols and droplets during Cytosponge procedures, which are being evaluated in large-scale research studies and National Health Service (NHS)implementation pilots to reduce endoscopy backlogs. We measured 18 Cytosponge and 37 EGD procedures using a particle counter (diameters = 0.3-25 µm), taking measurements 10 cm from the mouth. Two particle count analyses were performed: whole procedure and event-based. Direct comparison with duration-standardized EGD procedures shows that Cytosponge procedures produce 2.16× reduction (P < 0.001) for aerosols and no significant change for droplets (P = 0.332). Event-based analysis shows that particle production is driven by throat spray (aerosols: 138.1× reference, droplets: 16.2×), which is optional, and removal of Cytosponge (aerosols: 14.6×, droplets: 62.6×). Cytosponge burping produces less aerosols than EGD (2.82×, P < 0.05). Cytosponge procedures produce significantly less aerosols and droplets than EGD procedures and thus reduce two potential transmission routes for respiratory viruses.


Assuntos
Aerossóis e Gotículas Respiratórios , Medicina Estatal , Humanos , Boca , Endoscopia do Sistema Digestório , Aerossóis
5.
Endosc Int Open ; 11(10): E1001-E1004, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37941538

RESUMO

Background and study aims Upper gastrointestinal endoscopies are considered aerosol-generating procedures (AGP) that risk spread of airborne diseases such as SARS-CoV-2. We aimed to investigate where clinically approved bronchoscopy masks applied to patients during esophagogastroduodenoscopies can mitigate spread of aerosols and droplets. Patients and methods This study included patients undergoing routine upper gastrointestinal endoscopy in a standard endoscopy room and used a particle counter to measure size and number of particles 10 cm from the mouths of 49 patients undergoing upper gastrointestinal endoscopies, of whom 12 wore bronchoscopy masks and 37 did not (controls). Particle counts in the aerosol (≤ 5 µm diameter) and droplet (> 5 µm-diameter) size ranges were measured and averaged over the duration of procedures. Results The use of bronchoscopy masks offers a 47% reduction ( P = 0.01) in particle count for particles < 5 µm in diameter over the procedure duration (aerosols). Conclusions Bronchoscopy masks or similar are a simple, low-cost mitigation technique that can be used during outbreaks of respiratory diseases such as COVID-19 to improve safety and reduce fallow times.

7.
Gastrointest Endosc ; 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37993058

RESUMO

BACKGROUND AND AIMS: Inflammatory bowel disease (IBD) increases risk of dysplasia and colorectal cancer. Advanced endoscopic techniques allow for the detection and characterization of IBD dysplastic lesions, but specialized training is not widely available. We aim to develop and validate an online training platform to improve the detection and characterization of colonic lesions in IBD: OPTIC-IBD. METHODS: We designed a web-based learning module that includes surveillance principles, optical diagnostic methods, approach to characterization, classifications of colonic lesions, utilizing still images and videos. We invited gastroenterologists from Canada, Italy, and the UK, with a wide range of experience. Participants reviewed 24 educational videos of IBD colonic lesions, predicted histology, and rated their confidence. The primary endpoint was to improve accuracy in detecting dysplastic lesions following training on the platform. Furthermore, participants were randomized 1:1 to get additional training or not, with a final assessment occurring after 60 days. Diagnostic performance for dysplasia and rater confidence were measured. RESULTS: One hundred seventeen participants completed the study and were assessed for the primary endpoint. Diagnostic accuracy improved from 70.8% to 75.0% (p 0.002) following training, with the greatest improvements seen in less experienced endoscopists. Improvements in both accuracy and confidence were sustained after 2 months of assessment, although the group randomized to receive additional training did not improve further. Similarly, participants' confidence in characterizing lesions significantly improved between pre- and post-course (p<0.001), and it was sustained after 2 months of assessment. CONCLUSIONS: The OPTIC-IBD training module demonstrated that an online platform could improve participants' accuracy and confidence in the optical diagnosis of dysplasia in patients with IBD. The training platform can be widely available and improve endoscopic care for people with IBD. CLINICALTRIALS: gov NCT04924543.

8.
Dig Endosc ; 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-37988279

RESUMO

Precision endoscopy in the management of colorectal polyps and early colorectal cancer has emerged as the standard of care. It includes optical characterization of polyps and estimation of submucosal invasion depth of large nonpedunculated colorectal polyps to select the appropriate endoscopic resection modality. Over time, several imaging modalities have been implemented in endoscopic practice to improve optical performance. Among these, image-enhanced endoscopy systems and magnification endoscopy represent now well-established tools. New advanced technologies, such as endocytoscopy and confocal laser endomicroscopy, have recently shown promising results in predicting the histology of colorectal polyps. In recent years, artificial intelligence has continued to enhance endoscopic performance in the characterization of colorectal polyps, overcoming the limitations of other imaging modes. In this review we retrace the path of precision endoscopy, analyzing the yield of various endoscopic imaging techniques in personalizing management of colorectal polyps and early colorectal cancer.

9.
Gastrointest Endosc ; 2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37879543

RESUMO

BACKGROUND AND AIMS: Circumferential endoscopic submucosal dissection (cESD) in the esophagus has been reported to be feasible in small Eastern case series. We assessed the outcomes of cESD in the treatment of early esophageal squamous cell carcinoma (ESCC) in Western countries. METHODS: We conducted an international study at 25 referral centers in Europe and Australia using prospective databases. We included all patients with ESCC treated with cESD before November 2022. Our main outcomes were curative resection according to European guidelines and adverse events. RESULTS: A total of 171 cESDs were performed on 165 patients. En bloc and R0 resections rates were 98.2% (95% confidence interval [CI], 95.0-99.4) and 69.6% (95% CI, 62.3-76.0), respectively. Curative resection was achieved in 49.1% (95% CI, 41.7-56.6) of the lesions. The most common reason for noncurative resection was deep submucosal invasion (21.6%). The risk of stricture requiring 6 or more dilations or additional techniques (incisional therapy/stent) was high (71%), despite the use of prophylactic measures in 93% of the procedures. The rates of intraprocedural perforation, delayed bleeding, and adverse cardiorespiratory events were 4.1%, 0.6%, and 4.7%, respectively. Two patients died (1.2%) of a cESD-related adverse event. Overall and disease-free survival rates at 2 years were 91% and 79%. CONCLUSIONS: In Western referral centers, cESD for ESCC is curative in approximately half of the lesions. It can be considered a feasible treatment in selected patients. Our results suggest the need to improve patient selection and to develop more effective therapies to prevent esophageal strictures.

11.
Endoscopy ; 55(7): 681-682, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37379831
12.
Artigo em Inglês | MEDLINE | ID: mdl-37082739

RESUMO

Objectives: Upper gastrointestinal endoscopies are aerosol-generating procedures, increasing the risk of spreading airborne pathogens. We aim to quantify the mitigation of airborne particles via improved ventilation, specifically laminar flow theatres and portable high-efficiency particulate air (HEPA) filters, during and after upper gastrointestinal endoscopies. Methods: This observational study included patients undergoing routine upper gastrointestinal endoscopy in a standard endoscopy room with 15-17 air changes per hour, a standard endoscopy room with a portable HEPA filtration unit, and a laminar flow theatre with 300 air changes per hour. A particle counter (diameter range 0.3 µm-25 µm) took measurements 10 cm from the mouth. Three analyses were performed: whole procedure particle counts, event-based counts, and air clearance estimation using post-procedure counts. Results: Compared to a standard endoscopy room, for whole procedures we observe a 28.5x reduction in particle counts in laminar flow (p < 0.001) but no significant effect of HEPA filtration (p = 0.50). For event analysis, we observe for lateral flow theatres reduction in particles >5 µm for oral extubation (12.2x, p < 0.01), reduction in particles <5 µm for coughing/gagging (6.9x, p < 0.05), and reduction for all sizes in anesthetic throat spray (8.4x, p < 0.01) but no significant effect of HEPA filtration. However, we find that in the fallow period between procedures HEPA filtration reduces particle clearance times by 40%. Conclusions: Laminar flow theatres are highly effective at dispersing aerosols immediately after production and should be considered for high-risk cases where patients are actively infectious or the supply of personal protective equipment is limited. Portable HEPA filers can safely reduce the fallow time between procedures by 40%.

13.
Gastroenterology ; 164(7): 1180-1188.e2, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36871598

RESUMO

BACKGROUND & AIMS: Microscopic inflammation has significant prognostic value in ulcerative colitis (UC); however, its assessment is complex with high interobserver variability. We aimed to develop and validate an artificial intelligence (AI) computer-aided diagnosis system to evaluate UC biopsies and predict prognosis. METHODS: A total of 535 digitalized biopsies (273 patients) were graded according to the PICaSSO Histologic Remission Index (PHRI), Robarts, and Nancy Histological Index. A convolutional neural network classifier was trained to distinguish remission from activity on a subset of 118 biopsies, calibrated on 42 and tested on 375. The model was additionally tested to predict the corresponding endoscopic assessment and occurrence of flares at 12 months. The system output was compared with human assessment. Diagnostic performance was reported as sensitivity, specificity, prognostic prediction through Kaplan-Meier, and hazard ratios of flares between active and remission groups. We externally validated the model in 154 biopsies (58 patients) with similar characteristics but more histologically active patients. RESULTS: The system distinguished histological activity/remission with sensitivity and specificity of 89% and 85% (PHRI), 94% and 76% (Robarts Histological Index), and 89% and 79% (Nancy Histological Index). The model predicted the corresponding endoscopic remission/activity with 79% and 82% accuracy for UC endoscopic index of severity and Paddington International virtual ChromoendoScopy ScOre, respectively. The hazard ratio for disease flare-up between histological activity/remission groups according to pathologist-assessed PHRI was 3.56, and 4.64 for AI-assessed PHRI. Both histology and outcome prediction were confirmed in the external validation cohort. CONCLUSION: We developed and validated an AI model that distinguishes histologic remission/activity in biopsies of UC and predicts flare-ups. This can expedite, standardize, and enhance histologic assessment in practice and trials.


Assuntos
Colite Ulcerativa , Humanos , Colite Ulcerativa/diagnóstico , Colite Ulcerativa/patologia , Inteligência Artificial , Inflamação , Endoscopia , Prognóstico , Índice de Gravidade de Doença , Indução de Remissão , Colonoscopia , Mucosa Intestinal/patologia
14.
Endoscopy ; 55(S 01): E422-E423, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-36758632
15.
Gastroenterol Hepatol ; 46(6): 411-418, 2023.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35580739

RESUMO

BACKGROUND: Adenocarcinoma is preceded by chronic atrophic gastritis, gastric intestinal metaplasia and dysplasia. Trefoil factor 3 (TFF3) is a peptide secreted by goblet cells, which is abundantly present in intestinal metaplasia. AIM: To evaluate the utility of serum TFF3 as a non-invasive biomarker for the diagnosis of intestinal metaplasia and gastric cancer. METHODS: Single-center, cross-sectional study of 274 patients who consecutively underwent upper gastrointestinal endoscopy with gastric biopsies (updated Sydney system). TFF3 levels were measured in serum by a commercial ELISA kit. Patients with normal histology or chronic atrophic gastritis without intestinal metaplasia comprised the control group. In addition, 14 patients with invasive gastric cancer were included as a reference group. The association between TFF3 levels and intestinal metaplasia was assessed by logistic regression. RESULTS: Patients with intestinal metaplasia (n=110) had a higher median TFF3 level as compared to controls (n=164), 13.1 vs. 11.9ng/mL, respectively (p=0.024). Multivariable logistic regression showed a no significant association between TFF3 levels and intestinal metaplasia (OR=1.20; 95%CI: 0.87-1.65; p-trend=0.273). The gastric cancer group had a median TFF3 level of 20.5ng/mL, and a significant association was found (OR=3.26; 95%CI: 1.29-8.27; p-trend=0.013). CONCLUSION: Serum levels of TFF3 do not discriminate intestinal metaplasia in this high-risk Latin American population. Nevertheless, we confirmed an association between TFF3 levels and invasive gastric cancer.


Assuntos
Gastrite Atrófica , Helicobacter pylori , Lesões Pré-Cancerosas , Neoplasias Gástricas , Humanos , Neoplasias Gástricas/patologia , Fator Trefoil-3 , Estudos Transversais , Biomarcadores , Metaplasia/patologia , Mucosa Gástrica , Lesões Pré-Cancerosas/patologia
17.
Gastrointest Endosc ; 97(3): 422-434, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36283443

RESUMO

BACKGROUND AND AIMS: The aim of this study was to develop and externally validate a computer-aided detection (CAD) system for the detection and localization of Barrett's neoplasia and assess its performance compared with that of general endoscopists in a statistically powered multicenter study by using real-time video sequences. METHODS: In phase 1, the hybrid visual geometry group 16-SegNet model was trained by the use of 75,198 images and videos (96 patients) of neoplastic and 1,014,973 images and videos (65 patients) of nonneoplastic Barrett's esophagus. In phase 2, image-based validation was performed on a separate dataset of 107 images (20 patients) of neoplastic and 364 images (14 patients) of nonneoplastic Barrett's esophagus. In phase 3 (video-based external validation) we designed a real-time video-based study with 32 videos (32 patients) of neoplastic and 43 videos (43 patients) of nonneoplastic Barrett's esophagus from 4 European centers to compare the performance of the CAD model with that of 6 nonexpert endoscopists. The primary endpoint was the sensitivity of CAD diagnosis of Barrett's neoplasia. RESULTS: In phase 2, CAD detected Barrett's neoplasia with sensitivity, specificity, and accuracy of 95.3%, 94.5%, and 94.7%, respectively. In phase 3, the CAD system detected Barrett's neoplasia with sensitivity, specificity, negative predictive value, and accuracy of 93.8%, 90.7%, 95.1%, and 92.0%, respectively, compared with the endoscopists' performance of 63.5%, 77.9%, 74.2%, and 71.8%, respectively (P < .05 in all parameters). The CAD system localized neoplastic lesions with accuracy, mean precision, and mean intersection over union of 100%, 0.62, and 0.54, respectively, when compared with at least 1 of the expert markings. The processing speed of the CAD detection and localization were 5 ms/image and 33 ms/image, respectively. CONCLUSION: To our knowledge, this is the first study describing external (multicenter) validation of AI algorithms for the detection of Barrett's neoplasia on real-time endoscopic videos. The CAD system in this study significantly outperformed nonexpert endoscopists on real-time video-based assessment, achieving >90% sensitivity for neoplasia detection. This result needs to be validated during real-time endoscopic assessment.


Assuntos
Esôfago de Barrett , Neoplasias Esofágicas , Humanos , Esôfago de Barrett/diagnóstico , Esôfago de Barrett/patologia , Neoplasias Esofágicas/diagnóstico , Neoplasias Esofágicas/patologia , Esofagoscopia/métodos , Valor Preditivo dos Testes , Redes Neurais de Computação
18.
World J Gastroenterol ; 28(31): 4463-4466, 2022 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-36159016

RESUMO

We recently read with interest the article, "Novel frontiers of agents for bowel cleansing for colonoscopy". This is a practical narrative review, which could be of particular importance to clinicians in order to improve their current practice. Although we appreciate the venture of our colleagues, based on our in-depth analysis, we came across several minor issues in the article; hence, we present our comments in this letter. If the authors consider these comments further in their relevant research, we believe that their contribution would be of considerable importance for future studies.


Assuntos
Catárticos , Polietilenoglicóis , Catárticos/efeitos adversos , Colonoscopia , Humanos
19.
World J Gastroenterol ; 28(23): 2633-2635, 2022 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-35949348

RESUMO

We have recently read with interest the mini-review article "Therapeutic endoscopy for the treatment of post-bariatric surgery complications". The abovementioned article is a brief overview of the different endoscopic modalities employed in the management of bariatric surgery complications and represents an important decision support tool for clinicians to improve their current practice. Although we appreciate the endeavor of Larsen and Kozarek, based on our in-depth analysis, we came across several minor issues in this article; thus, we present our comments in this letter. In case the authors contemplate these comments in their relevant research, we believe that their contribution would be considerable for future studies.


Assuntos
Cirurgia Bariátrica , Derivação Gástrica , Laparoscopia , Obesidade Mórbida , Cirurgia Bariátrica/efeitos adversos , Gastrectomia/efeitos adversos , Derivação Gástrica/efeitos adversos , Humanos , Laparoscopia/efeitos adversos , Obesidade Mórbida/cirurgia , Complicações Pós-Operatórias/cirurgia , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos , Redução de Peso
20.
DEN Open ; 2(1): e97, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35873520

RESUMO

The World Endoscopy Organization Stomach and Duodenal Diseases Committee extracted minimum elements for screening and diagnosis of gastric cancer (GC) in aim to support countries that do not have national guidelines on screening and diagnosis of GC. Current national or international guidelines were collected worldwide and recommendations were classified according to the quality of evidence and were finalized through a modified Delphi method. The minimum elements consist of seven categories: [1] Extraction of high-risk patients of GC before esophagogastroduodenoscopy (EGD), [2] Patients who need surveillance of GC, [3] Method to ensure quality of EGD for detection of GC, [4] Individual GC risk assessment by EGD, [5] Extraction of high-risk patients of GC after EGD [6] Qualitative or differential diagnosis of GC by EGD, and [7] Endoscopic assessment to choose the therapeutic strategy for GC. These minimum elements will be a guide to promote the elimination of GC among countries with a high incidence of GC who lack national guidelines or screening programs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...